Plumbing: Recirc pump busted?

Home Repair - - If it ain't broken, don't fix it. Otherwise look here. 

Page 1 of 2       1 2 > last >> Bookmark this page:  YahooMyWeb Yahoo!  Google Google  Windows Live Favorites Windows Live  del.icio.us del.icio.us  digg digg  Add to Netscape Netscape
Subject Author Date
Plumbing: Recirc pump busted? dmax5705 07-06-2006
If you were  Registered and logged in, you could reply and use other advanced thread options
Posted by on July 6, 2006, 12:05 pm
just wanted to check if I have diagnosed this correctly.
When hot water is being drawn used in the house
(like in a shower) the inlet to the recirc pump, which is
next to the water heater in the garage, starts to run very
cold. I assume this is not normal and must mean that the
recirc pump is broken in some way?

my issue is that when taking a hot shower in a bathroom that
is closest to the water heater, the water turns very cold in parts
of the house that are further from the water heater (but closer
to the return pipe for the recirc pump). i.e. water in one shower
is nice and hot while water in the other shower is very cold
when both are running. the "cold" shower returns to nice and
hot when it is on by itself. I replace valves that could be causing
mixing and/or turned off secondary shutoffs and nothing worked.
Only thing I notice now is that the return pipe going to the recirc
pump gets very cold when I have both showers on and then one
of the showers run cold.

is there anything else i should try to make sure its the recirc
pump or not? My water heater is less than 2 years old and since
I get steaming hot water during this problem I assume its not the
issue.
recirc pump is 9 yrs old.


PexSupply Full Banner
Posted by JimL on July 6, 2006, 2:05 pm
On 6 Jul 2006 09:05:00 -0700, dmax5705@gmail.com wrote:

>just wanted to check if I have diagnosed this correctly.
>When hot water is being drawn used in the house
>(like in a shower) the inlet to the recirc pump, which is
>next to the water heater in the garage, starts to run very
>cold. I assume this is not normal and must mean that the
>recirc pump is broken in some way?
>
>my issue is that when taking a hot shower in a bathroom that
>is closest to the water heater, the water turns very cold in parts
>of the house that are further from the water heater (but closer
>to the return pipe for the recirc pump). i.e. water in one shower
>is nice and hot while water in the other shower is very cold
>when both are running. the "cold" shower returns to nice and
>hot when it is on by itself. I replace valves that could be causing
>mixing and/or turned off secondary shutoffs and nothing worked.
>Only thing I notice now is that the return pipe going to the recirc
>pump gets very cold when I have both showers on and then one
>of the showers run cold.
>
>is there anything else i should try to make sure its the recirc
>pump or not? My water heater is less than 2 years old and since
>I get steaming hot water during this problem I assume its not the
>issue.
>recirc pump is 9 yrs old.

Assuming that you are very wealthy and want to keep the energy
wasting recirc pump, then hire a plumber to check it out.

I'd guess that either you have a restriction in your lines (calcium
buildup), or you bought a way too small water heater.

The recirc pump should shut off when you are taking a shower and
using hot water. Most new installations I see either have a on/off
buttion near the sink/shower or a timer.

And you probably need more than one recirc pump, or better yet,
insulate and increase the size of your hot water line.





Posted by newsman on July 6, 2006, 2:51 pm
You need to describe your recirc system a little better. Is it one
where you have two sets of hot water pipes with the water moving in a
circuit through the two sets (and is the pump controlled by a
thermostat?); or is it one that uses the cold water pipes as part of the
hot water recirc system? If it's the former, is the pump pulling from
one hot water line and pushing the water into the water heater drain
pipe at the bottom of the tank? Are the hot and cold pipes connected to
the correct stubs at the top of the water heater? BTW, if you can hear
the pump motor running, odds are very high (but not certain) that the
pump rotor is turning. Usually when recirc pumps fail, it's due to the
motor dying.


dmax5705@gmail.com wrote:
> just wanted to check if I have diagnosed this correctly.
> When hot water is being drawn used in the house
> (like in a shower) the inlet to the recirc pump, which is
> next to the water heater in the garage, starts to run very
> cold. I assume this is not normal and must mean that the
> recirc pump is broken in some way?
>
> my issue is that when taking a hot shower in a bathroom that
> is closest to the water heater, the water turns very cold in parts
> of the house that are further from the water heater (but closer
> to the return pipe for the recirc pump). i.e. water in one shower
> is nice and hot while water in the other shower is very cold
> when both are running. the "cold" shower returns to nice and
> hot when it is on by itself. I replace valves that could be causing
> mixing and/or turned off secondary shutoffs and nothing worked.
> Only thing I notice now is that the return pipe going to the recirc
> pump gets very cold when I have both showers on and then one
> of the showers run cold.
>
> is there anything else i should try to make sure its the recirc
> pump or not? My water heater is less than 2 years old and since
> I get steaming hot water during this problem I assume its not the
> issue.
> recirc pump is 9 yrs old.
>

Posted by HerHusband on July 7, 2006, 11:12 am
> When hot water is being drawn used in the house
> (like in a shower) the inlet to the recirc pump, which is
> next to the water heater in the garage, starts to run very
> cold. I assume this is not normal and must mean that the
> recirc pump is broken in some way?

My first guess would be you have air in the recirculating line and the pump
isn't pumping water. Have you tried bleeding the air bubbles out of the
system?

Also, it sounds like your system may be missing a check valve on the
recirculation line. Cold water shouldn't be able to work backwards through
the system.

If you have had the system apart, you may want to make sure the pump isn't
installed backwards.

Anthony

Posted by Not@home on July 7, 2006, 11:53 am
I have a circulating system that works without a pump, so I'll not say
anything about the pump, other than that I assume it is plumbed to the
bottom of the water heater. Incidentally, the two plumbers I have had
work on my system, while licensed, didn't know anything about how the
system worked, and one even installed the check valve backward.

My guess is that you don't have a functioning check valve, so when you
turn on the hot water, you draw both hot water from the top of the
heater, and cold water from the bottom. That would explain why the line
near the pump is cold. I would suspect the shower that is nearest the
line drawing hot water from the top of the tank would get mostly hot
water, while the shower that is nearest the return line drawing cold
water would get more cold than hot water. Its possible that when using
only one shower, you get enough hot (even when mixed with some cold)
that it feels hot, while when using both showers you are drawing more
water, and get the imbalance you describe. I know my system worked
without a check valve, but I got hotter water after I added the check
valve, and got the plumber to point the arrow the right way.
Incidentally, when he came back to redo the check valve, he said he had
been talking about my system with some of the other plumbers, and they
weren't certain it would work, so at least some of them knew about it.
Mine works without a pump because I have an old house with about a
fifteen foot vertical rise from the heater in the basement to the
upstairs bath, and I insulated that rise, while leaving the return
uninsulated. Thanks to gravity, the hotter water rises naturally and
the system works.

dmax5705@gmail.com wrote:

> just wanted to check if I have diagnosed this correctly.
> When hot water is being drawn used in the house
> (like in a shower) the inlet to the recirc pump, which is
> next to the water heater in the garage, starts to run very
> cold. I assume this is not normal and must mean that the
> recirc pump is broken in some way?
>
> my issue is that when taking a hot shower in a bathroom that
> is closest to the water heater, the water turns very cold in parts
> of the house that are further from the water heater (but closer
> to the return pipe for the recirc pump). i.e. water in one shower
> is nice and hot while water in the other shower is very cold
> when both are running. the "cold" shower returns to nice and
> hot when it is on by itself. I replace valves that could be causing
> mixing and/or turned off secondary shutoffs and nothing worked.
> Only thing I notice now is that the return pipe going to the recirc
> pump gets very cold when I have both showers on and then one
> of the showers run cold.
>
> is there anything else i should try to make sure its the recirc
> pump or not? My water heater is less than 2 years old and since
> I get steaming hot water during this problem I assume its not the
> issue.
> recirc pump is 9 yrs old.
>

Page 1 of 2       1 2 > last >>
Similar ThreadsPosted
Sump Pump Plumbing Question April 28, 2008, 1:34 pm
Pump house Plumbing Project for new Tanks and Cottage March 4, 2007, 11:10 pm
Is frost free sillcock busted? August 18, 2005, 11:00 am
Busted my carport support beam. December 7, 2005, 12:53 pm
Busted furnace condensate drain trap November 7, 2006, 5:52 pm
Replacing a busted pane in my french door July 17, 2008, 12:53 am
Re: U.S. Senator Busted: Sucking Dick in Airport Bathroom August 31, 2007, 7:07 am
Swelling clay, rising patio block, busted stucco ,,, question September 21, 2006, 3:28 pm
Water Storage Tank - Plumbing the Pump & Pressure Tank August 7, 2006, 3:29 pm
Plumbing Code - Can I tie my bathroom exaust fan into the main plumbing vent to the outside. October 31, 2006, 2:43 pm

Contact Us | Privacy Policy

XML SitemapXML Sitemap