Posted by Todd on July 6, 2007, 12:44 pm
I have a 3/4 HP pool pump motor that has a centrifugal switch in it.
The start windings have gone bad so it will not start on its own but
will run fine if I "give it a hand" to get started. My question is
can I put a start capacitor on the main windings to get it going? Will
it work? What size capacitor should I try? Capacitor are far cheaper
than pool pumps so giving it a try would be a low bux solution.
Here are the details
3/4 HP 115 VAC
3450 RPM
8.5 A
Continuous Duty
Service Factor 1.0 (BTW, what does the "service factor" # indicate?

Thanks for the info.
Todd


Posted by Dave Martindale on July 6, 2007, 1:10 pm
>I have a 3/4 HP pool pump motor that has a centrifugal switch in it.
>The start windings have gone bad so it will not start on its own but
>will run fine if I "give it a hand" to get started. My question is
>can I put a start capacitor on the main windings to get it going? Will
>it work? What size capacitor should I try? Capacitor are far cheaper
>than pool pumps so giving it a try would be a low bux solution.

If the winding is bad, the motor is dead.

Capacitor-start and capacitor-run motors put the capacitor in series
with a second winding. The capacitor causes a phase shift in the
current in the second winding so that the magnetic fields of the
(unshifted) main winding and the second winding (added together)
rotates. A split phase motor gets the phase shift by making the second
winding higher resistance or higher inductance, without a capacitor.

But all of these methods need the second winding to work. With one
single winding, there is no rotating magnetic field, just a pulsating
one. That will keep the motor rotating once started, but won't start
it. A capacitor on the main winding will cause a phase shift with
respect to incoming power, but there's still no rotating field.

He's dead, Jim - unless you get a motor shop to repair or rewind the
start winding.

        Dave

Similar ThreadsPosted
Pool pump motor - fried? December 2, 2005, 12:06 pm
New pool pump motor overheating March 31, 2007, 11:48 pm
Pool Pump Question May 21, 2006, 5:46 pm
Swimming Pool Pump Question January 9, 2006, 4:36 pm
above ground pool pump question January 8, 2007, 6:48 am
Swimming pool pump sizing question. November 15, 2006, 5:33 pm
Help! Pool motor starts intemittently September 5, 2006, 1:36 pm
Help! Pool motor starts intemittently September 5, 2006, 1:37 pm
Pool motor switch zapped July 8, 2007, 6:56 pm
Replacing well pump motor June 30, 2005, 6:28 pm

Contact Us | Privacy Policy

XML SitemapXML Sitemap