Home Page link

Putting electrical outlets in brick?

Home Repair - - If it ain't broken, don't fix it. Otherwise look here. 

Page 1 of 2       1 2 > last >> Bookmark this page:  YahooMyWeb Yahoo!  Google Google  Windows Live Favorites Windows Live  del.icio.us del.icio.us  digg digg  Add to Netscape Netscape
Subject Author Date
Putting electrical outlets in brick? W. Wells 07-16-2006
If you were  Registered and logged in, you could reply and use other advanced thread options
Posted by W. Wells on July 16, 2006, 8:35 am
I am installing an outlet on a porch of a brick house. Do you just knock out
a space for the box and wedge it in or is there some special way in brick? I
presume that you should put a special cover on the outlet to protect from
the weather.



Posted by on July 16, 2006, 10:14 am
Pics?

Most likely you would want to surface mount it.


Posted by Seymour Bigby-Heinz on July 16, 2006, 10:24 am

>I am installing an outlet on a porch of a brick house. Do you just knock out
>a space for the box and wedge it in or is there some special way in brick? I
>presume that you should put a special cover on the outlet to protect from
>the weather.
>

You certainly can knock out a brick or two and place your outlet in
the opening and replace partial bricks to fill in the space, plus
mortar. I've seen this type of outlet, with spring-loaded outlet
covers on some houses.

However, it might be better to mount an outlet box to the surface of
the bricks. That way would have less damage to the brick surface
(just enough to let the power cable through), but can have similar or
better weather protection. There are weather-resistant outlet boxes
available at most home centers.

It probably depends upon where your outlet is located and whether or
not a lot of water drains down the brick surface. Either way, GFCI!

Sy

Posted by hallerb@aol.com on July 16, 2006, 10:34 am
Been there done this:(

Trust me long term your way better off with a outdoor sealed box just
mounted to the brick!

More secure way less work and no moisture issues causing box rusting
over the years.

I put one in the bricks, admittely over 20 years ago and have redone it
for a variety of reasons over the years. Mostly moisture leaking
inside. I finally left a opening at the bottom so any water that gets
in has a easy way out.

The surface monunted boxes have NEVER had a problem, and some are in
nearly as long.


Posted by W. Wells on July 16, 2006, 12:28 pm
Thanks for the advise. I doubt if I would get water drainage except from
washing off the porch with a hose, and I'm sure the inset would look better,
but the sealed box sounds more practical. ( If my wife will go along )
> Been there done this:(
>
> Trust me long term your way better off with a outdoor sealed box just
> mounted to the brick!
>
> More secure way less work and no moisture issues causing box rusting
> over the years.
>
> I put one in the bricks, admittely over 20 years ago and have redone it
> for a variety of reasons over the years. Mostly moisture leaking
> inside. I finally left a opening at the bottom so any water that gets
> in has a easy way out.
>
> The surface monunted boxes have NEVER had a problem, and some are in
> nearly as long.
>



Page 1 of 2       1 2 > last >>
Similar ThreadsPosted
Putting in new outlets in the garage June 8, 2008, 4:41 pm
Putting two exposed work electrical boxes next to each other. July 11, 2005, 1:20 pm
Putting expanding foam into electrical outlet November 16, 2005, 5:31 pm
electrical outlets April 16, 2007, 12:48 am
Question about red electrical outlets January 4, 2006, 2:19 pm
No boxes behind electrical outlets August 2, 2006, 8:22 am
Electrical outlets near doorways. November 27, 2006, 6:43 pm
Ungrounded Electrical outlets December 21, 2006, 5:52 pm
Numbering electrical outlets June 29, 2008, 6:02 am
replacing older electrical outlets January 30, 2006, 11:44 am

Contact Us | Privacy Policy