Posted by SQLit on June 14, 2005, 8:40 pm
> In looking for a new AC, I ran across two with the same BTUs, same
> manufacturer, same energy efficiency, but the difference is that one
> removes 25% more humidity per 24 hr than the other. (Basically, that
> one is the new model and the other is the discontinued but-still
> -available-until-sold-out version of the same AC).
>
> How can an AC be remodeled to remove more humidity?
>
> Sue(tm)
> Lead me not into temptation... I can find it myself!
Short answer yes. I had a American Standard with a VFD on the air handler.
Startup of the compressor the fan would ramp up to 30%... stay there for a
minute. Running 5 tons of cooling through the coil and only 30 % of the air
volume it removed a lot more than a single speed unit.
Check the specs carefully if there is no other difference in the mechanical
stuff, look especially at the specs for the blower and its operation.
Might be other ways to do it I know that method works.
|