Re: Forced Air Furnace not reaching thermostat setting

Home Repair - - If it ain't broken, don't fix it. Otherwise look here. 

Bookmark this page:  YahooMyWeb Yahoo!  Google Google  Windows Live Favorites Windows Live  del.icio.us del.icio.us  digg digg  Add to Netscape Netscape
Subject Author Date
Re: Forced Air Furnace not reaching thermostat setting Joseph Meehan 02-20-2008
If you were  Registered and logged in, you could reply and use other advanced thread options
Posted by Joseph Meehan on February 20, 2008, 2:08 pm
Sorry if this is a duplicate. Please let me know if it is, it appears it
did not make it the first time.


> Get the instructions for the thermostat out and take a look for
> anything a bout an anticipator. It may not be set properly for your
> furnace.
>
> The other idea that comes to mind is that a high heat sensor on the
> furnace is kicking in for some reason.
>
> --
> Joseph Meehan
>
> Dia 's Muire duit
>
>
>
>> My Amama 115,000 btu forced air system (1987) with White-Rodgers
>> controller is not reaching its thermostat setting. My thermostat is a
>> Honeywell set-back model. The furnace has a particular problem in the
>> morning to raise the temperature from the low temperature that is used
>> at night.
>>
>> 1. Thermostat calls for heat.
>> 2. Induced Draft motor starts
>> 3. Furnace makes a clicking noise and ignitor turns on
>> 4. Blower turns on.
>> 5. High temperature limit turns off burners (after 4 minutes)
>> 6. Ignitor turns on
>> 7. Gas lights and stays on for about (4 minutes)
>> 8. Furnace turns off without reaching thermostat setting
>>
>> I can shut the power off to reset the furnace and it will light off
>> again for about 15 minutes again. I have changed the Flame senor to
>> be sure that it is not causing the problem.
>>
>> Is there anything anyone has to offer on what might be tripping the
>> furnace?
>

Similar ThreadsPosted
Forced Air Furnace not reaching thermostat setting February 19, 2008, 4:04 pm
Forced Air Furnace not reaching thermostat setting February 19, 2008, 4:04 pm
Heat Pump Not Reaching Heat Setting January 16, 2008, 8:40 pm
Thermostat setting? October 8, 2005, 8:20 am
thermostat setting January 5, 2008, 12:06 am
Setting inside thermostat? December 29, 2005, 10:59 am
run my oil forced air furnace once a month in the summer to keep the furnace from rusting July 4, 2006, 9:59 am
forced hot air furnace November 6, 2006, 10:29 pm
Need advice for setting furnace draft control. September 3, 2006, 5:56 pm
installed new forced air furnace, might be too big. November 8, 2005, 1:48 pm

Contact Us | Privacy Policy

XML SitemapXML Sitemap