> I fix one thing another breaks. Just got my
> back flow assembly replaced last week. Yesterday morning I noticed the
> sound of water flowing through pipes in my back yard. It was my
> irrigation system. One of the selenoid valves is not closing properly.
> I know nothing about these valves assemblies. Could it be only the
> selenoid or is it likely the whole assembly? Is current supplied when
> the valve is open or closed?
>
> Thanks,
>
> Matt
>
Two possibilities, one is that dirt got in the valve from your other
repair, not allowing the valve to fully close. Try cycling that station a
couple of times, or better yet, take a head off that station and purge
the line. If that doesn't work, then the spring in the valve is probably
weak. I had the same problem and had to replace the valve. A lot of
digging and hard work. They do sell the internals for valves, but mine is
20 years old, and they didn't sell them any more.
Good luck.
|