Sump Pump Clunk After Backup Pump Install

Home Repair - - If it ain't broken, don't fix it. Otherwise look here. 

Bookmark this page:  YahooMyWeb Yahoo!  Google Google  Windows Live Favorites Windows Live  del.icio.us del.icio.us  digg digg  Add to Netscape Netscape
Subject Author Date
Sump Pump Clunk After Backup Pump Install blah@blah.com 04-18-2007
If you were  Registered and logged in, you could reply and use other advanced thread options
Posted by blah@blah.com on April 18, 2007, 9:42 am


Had a Zoeller Model 98 sump pump with a Flotec checkvalve. All was
good and the pump operated quitely.

This weekend, I added a Basement Watchdog Big Dog battery backup pump
to supplement my Zoeller. I wye'd off the 1.5" main line and added
two new flapper type checkvalves from Lowes (each one about 12" above
the pump). I discarded the old Flotec flapper type checkvalve.

The system seems to work fine. Only difference is that now when the
Zoeller cycles off, I hear a mild clunk that I never heard before.
Any idea how I might quiet it down?

BTW, there are 1/8" downward angled weep holes just below each of the
checkvalves to prevent air lock.

Thanks,
Kevin


Posted by hallerb@aol.com on April 18, 2007, 10:28 am


> Had a Zoeller Model 98 sump pump with a Flotec checkvalve. =A0All was
> good and the pump operated quitely.
>
> This weekend, I added a Basement Watchdog Big Dog battery backup pump
> to supplement my Zoeller. =A0I wye'd off the 1.5" main line and added
> two new flapper type checkvalves from Lowes =A0(each one about 12" above
> the pump). =A0 I discarded the old Flotec flapper type checkvalve.
>
> The system seems to work fine. =A0Only difference is that now when the
> Zoeller cycles off, I hear a mild clunk that I never heard before.
> Any idea how I might quiet it down?
>
> BTW, there are 1/8" downward angled weep holes just below each of the
> checkvalves to prevent air lock.
>
> Thanks,
> Kevin

probably the check valves.

Honestly if I were you I would run a completely seperate line for the
backup pump. In case that single drain line ever fails or a check
valve malfunctions where the pump could just cycle water endlessely.

Just get the water out of the immedioate area, like out a wall if it
can run away from building.

I am a belt AND suspenders kinda guy.



Posted by Toller on April 18, 2007, 11:03 am



> Had a Zoeller Model 98 sump pump with a Flotec checkvalve. All was
> good and the pump operated quitely.
>
> This weekend, I added a Basement Watchdog Big Dog battery backup pump
> to supplement my Zoeller. I wye'd off the 1.5" main line and added
> two new flapper type checkvalves from Lowes (each one about 12" above
> the pump). I discarded the old Flotec flapper type checkvalve.
>
> The system seems to work fine. Only difference is that now when the
> Zoeller cycles off, I hear a mild clunk that I never heard before.
> Any idea how I might quiet it down?
>
> BTW, there are 1/8" downward angled weep holes just below each of the
> checkvalves to prevent air lock.
>
> Thanks,
> Kevin

probably the check valves.

Honestly if I were you I would run a completely seperate line for the
backup pump. In case that single drain line ever fails or a check
valve malfunctions where the pump could just cycle water endlessely.

Just get the water out of the immedioate area, like out a wall if it
can run away from building.

I am a belt AND suspenders kinda guy.
_______________

I installed a water powered back up for someone. If it breaks, water will
pour into the sump, AND the main sump pump will mainly pump through the
broken back up rather than out. Sure isn't what I would want in my
basement; I am not sure belt and suspenders are enough there. I wouldn't be
concerned except that the pump was so poorly made that failure is quite
possible; he bought the pump....




Posted by blah@blah.com on April 18, 2007, 1:04 pm


I'll put the Flotec check valve back in and see what happens then.

Thanks guys...

Kevin


Posted by mm on April 19, 2007, 4:06 am



>
>I installed a water powered back up for someone. If it breaks, water will

I have sump pump issues, so I really want to understand this, but I
can't follow this paragraph at all. If the water powered backup
breaks or if the electric sump pump breaks?

>pour into the sump,

Water will pour into the sump if the water powered back up breaks?
Only a certain kind of breaking at most, and wouldn't the water just
blow out the designed exit if the valve fails?

> AND the main sump pump will mainly pump through the
>broken back up rather than out.

The two pumps are connected to each other? The only water powered one
I know sucks the water up to the ceiling and blows it out sideways,
like a perfume atomizer but using water instead of air, and isn't
connected to the original pump at all, except the input tube sits in
the same water.

> Sure isn't what I would want in my
>basement; I am not sure belt and suspenders are enough there. I wouldn't be
>concerned except that the pump was so poorly made that failure is quite
>possible; he bought the pump....

What brand of pump did he buy? I don't want to buy the same thing.


Similar ThreadsPosted
sump pump backup August 14, 2007, 11:39 am
Best idea for a BACKUP sump pump March 28, 2007, 1:19 pm
Battery Backup Sump Pump July 17, 2007, 9:58 am
Sump Pump Backup battery question April 3, 2006, 3:07 pm
Water pressure backup sump pump October 29, 2006, 9:36 pm
Designing battery backup sump pump. January 11, 2007, 3:17 pm
DIY Battery Backup Sump Pump System June 30, 2008, 9:42 am
Sump pump float switch: separate from pump? January 15, 2006, 12:25 pm
Ejector pump backup? August 14, 2007, 12:15 pm
What to do with my sump pump?? February 18, 2006, 3:15 pm

Contact Us | Privacy Policy

XML SitemapXML Sitemap