Vexing plumbing problem Dan Musicant 04-18-2008
If you were  Registered and logged in, you could reply and use other advanced thread options
Posted by man@privacy.net on April 21, 2008, 2:12 pm
On Sat, 19 Apr 2008 01:53:18 GMT, Wayne Whitney

:
:> replace the galvanized with PEX quick easy permanent solution, add
:> valves to isolate each fixture in case of future troubles.........
:
:PEX is not approved in the OP's location. Wayne

Thanks, Wayne, you'd know! Good luck on your kitchen, BTW!

Posted by man@privacy.net on April 21, 2008, 2:10 pm
On Fri, 18 Apr 2008 17:09:35 -0700 (PDT), "hallerb@aol.com"

:replace the galvanized with PEX quick easy permanent solution, add
:valves to isolate each fixture in case of future troubles.........
:
:galvanized is like culprit since you say you generally have a
:restricted flow

I'm sorry, when I said restricted flow I meant that I don't ever open
the stem up to anything like full flow, I only open it to around 2-3
quarts/minute for sustained flow. I never just open it up full blast. I
don't know that the flow through the pipe is particularly restricted by
virtue of the pipe having deteriorated. Still, your idea of a PEX
replacement may be a great idea. Thanks.

Dan


Posted by Wayne Whitney on April 18, 2008, 6:58 pm

> I shut off the water at the cold water shutoff, remove the stem from
> the hot water valve at the kitchen sink and see one, two or three
> tiny grains of sand, flaked iron, who knows what it is, but it's
> very tiny.

There's a screen on the water inlet on your tankless hot water heater.
You may wish to shut off the water supply to your tankless, remove the
screen and check it. If you see the same particles there, you know
they are not from your water heater but probably from your old water
piping. Obviously the particles at the sink would be from piping
after the water heater, since the particles can't make it past the
screen.

Another thing you may try is to flush the hot water line, although you
may have done this after installing the new water heater and/or
faucet. You remove the aerator from the kitchen faucet, turn the
faucet to full on, and let it turn for a couple minutes. Without the
aerator the flow is a bit chaotic, so expect water to splash around a
bit. After flushing you could clean the valve seat as you have been
doing, and then see if the problem still recurs.

Good luck.

Cheers, Wayne

Posted by man@privacy.net on April 21, 2008, 2:21 pm
On Fri, 18 Apr 2008 22:58:52 GMT, Wayne Whitney

:
:> I shut off the water at the cold water shutoff, remove the stem from
:> the hot water valve at the kitchen sink and see one, two or three
:> tiny grains of sand, flaked iron, who knows what it is, but it's
:> very tiny.
:
:There's a screen on the water inlet on your tankless hot water heater.
:You may wish to shut off the water supply to your tankless, remove the
:screen and check it. If you see the same particles there, you know
:they are not from your water heater but probably from your old water
:piping. Obviously the particles at the sink would be from piping
:after the water heater, since the particles can't make it past the
:screen.
:
:Another thing you may try is to flush the hot water line, although you
:may have done this after installing the new water heater and/or
:faucet. You remove the aerator from the kitchen faucet, turn the
:faucet to full on, and let it turn for a couple minutes. Without the
:aerator the flow is a bit chaotic, so expect water to splash around a
:bit. After flushing you could clean the valve seat as you have been
:doing, and then see if the problem still recurs.
:
:Good luck.
:
:Cheers, Wayne

I've never flushed the pipes, IIRC. Noone suggested it to me, and it
never occurred to me until a few days ago when I started this thread.
Still haven't done it but I definitely will try that and see how it
goes. I don't think I even keep the aerator on there. Is there a good
reason to do so? I thought it was more or less a flow restriction device
(which I don't need since I self-regulate that!), or a means of
filtering (post stem!), and since I don't cook with or drink hot water I
figure why bother?

Thanks for the info on PEX. Actually, I hadn't thought about the codes.
So, if I do decide to replace the old galvanized I'm restricted to more
galvanized or copper?

Dan

Posted by Wayne Whitney on April 21, 2008, 11:00 pm
On 2008-04-21, Dan Musicant (man@privacy.net) <Dan> wrote:

> I don't think I even keep the aerator on there. Is there a good
> reason to do so? I thought it was more or less a flow restriction
> device (which I don't need since I self-regulate that!), or a means
> of filtering (post stem!), and since I don't cook with or drink hot
> water I figure why bother?

Without an aerator, the flow will be very chaotic if you ever open it
up all the way. An aerator can and will limit flow, but that
shouldn't be a problem for you.

> So, if I do decide to replace the old galvanized I'm restricted to more
> galvanized or copper?

Any water supply pipes you replace should be copper--it doesn't make
sense to install galvanized given its performance, and PEX is not
approved here, as previously mentioned. To connect the new copper to
your existing galvanized, the best solution is to use a 6" brass
nipple (or stainless steel? not sure if stainless is OK) with a female
threaded galvanized fitting on one side, and a copper sweat to female
threaded adapter on the other end. A "nipple" is just a short section
of (threaded) pipe.

Cheers, Wayne

Page 4 of 5       < 1 2 3 > last >>
Similar ThreadsPosted
Plumbing problem December 31, 2005, 10:48 am
Plumbing problem September 19, 2006, 11:32 pm
Plumbing problem? September 26, 2006, 10:10 pm
Plumbing problem October 13, 2006, 10:37 am
Plumbing problem February 16, 2007, 8:58 am
Plumbing problem question August 18, 2005, 7:11 pm
Outdoor Plumbing Problem October 27, 2005, 12:01 pm
Paranoid Plumbing Problem October 30, 2005, 6:01 pm
Need solution to plumbing problem January 4, 2007, 8:04 am
Weird plumbing problem May 8, 2007, 9:51 pm

Contact Us | Privacy Policy

XML SitemapXML Sitemap