I have a gear-driven control valve on my water softener. I am not
sure of the model but the only sticker on the valve (on the bottom of
the plate under the valves) says "brookfield, WI" along with the
patent information.

My problem is that the valve leaks where a vertical metal rod comes
out of a plastic 'volcano' shaped bushing. THe rod runs vertical and
attaches with a screw that runs through a 1/2" slot on it's triangular
metal plate (on the top of the rod) to the back of the large center
gear (On the front of this gear are the time labels to set the time of
day for regeneration).

Do I have to replace the entire control valve (it is only a year old)
or can it be fixed?

Posted by Gary Slusser on January 29, 2008, 1:32 pm
On Jan 26, 11:52 am, lowcountryho...@gmail.com wrote:
> I have a gear-driven control valve on my watersoftener. I am not
> sure of the model but the only sticker on the valve (on the bottom of
> the plate under the valves) says "brookfield, WI" along with the
> patent information.
>
> My problem is that the valve leaks where a vertical metal rod comes
> out of a plastic 'volcano' shaped bushing. THe rod runs vertical and
> attaches with a screw that runs through a 1/2" slot on it's triangular
> metal plate (on the top of the rod) to the back of the large center
> gear (On the front of this gear are the time labels to set the time of
> day for regeneration).
>
> Do I have to replace the entire control valve (it is only a year old)
> or can it be fixed?

You have a Fleck 5600 control valve. Go to
www.fleckcontrols.com and download the 5600 Econominder or time clock
version service manual. Match the face of your control to the
pictures.

The leak is probably the piston stem o-ring in the end cap or the
Teflon coating is worn on the piston stem. I or other dealers sell the
parts.

Gary Slusser
Quality Water Associates

Similar ThreadsPosted
gas water heater control valve question April 2, 2008, 1:18 pm
water valve leaks if not fully opened or closed. Problem? May 21, 2007, 12:32 am
culligan softener valve out of sync March 1, 2007, 7:05 am
AC leaks air at valve in attic July 18, 2005, 11:05 pm
shower control valve June 8, 2008, 11:24 am
Looking for an Itt/General Control Valve MR4J January 11, 2006, 3:51 am
Culligan control valve question July 2, 2006, 1:36 pm
leaking sprinkler control valve July 13, 2007, 9:50 am
gaslogs - valve/control knob November 20, 2007, 1:09 pm
new Kohler toilet tank leaks - is fill valve pre-installed? July 22, 2005, 9:58 am

Contact Us | Privacy Policy

XML SitemapXML Sitemap