I recently had a Weil McLain boiler installed. Huge improvement over
the old coal converted asbestos coated boiler that I replaced.
I noticed that when the boiler begins to fire up, it runs for about 10
seconds before ingition. It also runs for about the same amount of
time when the flame goes out. Is this normal?


Posted by RBM on October 17, 2006, 6:58 am


I haven't read the documentation on these boilers yet, but I believe there
is a time delay from when the burner starts, until that solenoid valve on
the left side of the gun opens, allowing oil to flow


>I recently had a Weil McLain boiler installed. Huge improvement over
> the old coal converted asbestos coated boiler that I replaced.
> I noticed that when the boiler begins to fire up, it runs for about 10
> seconds before ingition. It also runs for about the same amount of
> time when the flame goes out. Is this normal?
>



Posted by Pete C. on October 17, 2006, 9:44 am


mstrspy wrote:
>
> I recently had a Weil McLain boiler installed. Huge improvement over
> the old coal converted asbestos coated boiler that I replaced.
> I noticed that when the boiler begins to fire up, it runs for about 10
> seconds before ingition. It also runs for about the same amount of
> time when the flame goes out. Is this normal?

Those are pre and post purge cycles. It runs the blower without the oil
on for 10 seconds to push fresh air into the combustion chamber,
potentially pushing out fuel vapors from a failed ignition cycle and
also getting the chimney draft flowing before ignition. It shuts off the
oil and continues the post purge blower cycle for 10 seconds to clear
remaining exhaust from the combustion chamber and chimney.

Pete C.

Similar ThreadsPosted
Weil-McLain Ultra Boiler January 15, 2006, 1:43 am
Weil Mclain Boiler Rumbles September 30, 2007, 10:51 pm
Bleeding Weil McLain gas heated boiler January 27, 2007, 2:37 pm
Problems with Noisy Flapper on Weil-McLain Oil Boiler February 7, 2005, 10:29 pm
Buderus vs. Weil-McLain boiler, and expansion tank question July 31, 2007, 9:51 am
Weil McLain vs Williamson Boilers? November 8, 2005, 7:31 am
Weil McLain Boilers Any Good? July 4, 2006, 10:53 am
Weil-McLain vs Peerless furnace? July 31, 2006, 3:16 pm
Buderus versus Weil Mclain September 6, 2007, 11:28 pm
Weil-McLain Ultra and direct sunlight April 6, 2006, 9:35 am

Contact Us | Privacy Policy

XML SitemapXML Sitemap