Posted by on June 19, 2006, 6:25 pm

A neighbor installed a window A/C

It's tilting quite a bit out the window.

I suggested he level it for better operation.

He claims it shouldnt make any difference.

????

<rj>

Posted by Edwin Pawlowski on June 19, 2006, 7:13 pm

>
> A neighbor installed a window A/C
>
> It's tilting quite a bit out the window.
>
> I suggested he level it for better operation.
>
> He claims it shouldnt make any difference.
>
> ????

Yes, it will make a difference. The AC has a drain pan that catches the
condensate. The water is picked up by the slinger ring condenser fan and is
slung onto the coil giving it a bit more cooling. No drips, better cooling.
Make it level.



Posted by Abe on June 19, 2006, 9:25 pm
>Yes, it will make a difference. The AC has a drain pan that catches the
>condensate. The water is picked up by the slinger ring condenser fan and is
>slung onto the coil giving it a bit more cooling. No drips, better cooling.
>Make it level.
Ed, according to the Friedrich manual that came with my in-wall AC,
they are very specific that the unit should be mounted with a
half-bubble lean toward the outside to prevent overfilling of the pan,
and still have slinging action. They specifically say that mounting it
level can result in water leaking back into the house.


Posted by Edwin Pawlowski on June 19, 2006, 9:35 pm

> Ed, according to the Friedrich manual that came with my in-wall AC,
> they are very specific that the unit should be mounted with a
> half-bubble lean toward the outside to prevent overfilling of the pan,
> and still have slinging action. They specifically say that mounting it
> level can result in water leaking back into the house.
>

I don't think a half bubble will make a difference on any brand, but that is
hardly visible.



Posted by Abe on June 19, 2006, 9:59 pm
>> Ed, according to the Friedrich manual that came with my in-wall AC,
>> they are very specific that the unit should be mounted with a
>> half-bubble lean toward the outside to prevent overfilling of the pan,
>> and still have slinging action. They specifically say that mounting it
>> level can result in water leaking back into the house.
>I don't think a half bubble will make a difference on any brand, but that is
>hardly visible.
You're right about the lean being almost invisible. It's really not
detectable unless you really look closely. It is enough lean, however,
to keep the water from pooling all the way to the house side of the
pan.


Similar ThreadsPosted
Need Help Install Window Air Conditioner in Storm Window Frame June 18, 2006, 10:28 pm
Installing a Window Air Conditioner into a Wide Window June 6, 2008, 5:52 pm
Milgard window and window air conditioner May 14, 2006, 1:18 pm
Whirlpool Window Air Conditioner July 26, 2005, 12:50 pm
Window Air Conditioner Panels July 5, 2005, 8:50 pm
Window Air Conditioner Angle? May 10, 2007, 9:03 pm
Window Air conditioner not working. June 7, 2007, 6:45 pm
Rotating a window air conditioner? July 2, 2007, 3:48 am
Installing Window Air Conditioner December 8, 2007, 5:55 pm
quiet window air conditioner? May 26, 2008, 7:44 pm

Contact Us | Privacy Policy

XML SitemapXML Sitemap