Posted by Red Green on May 10, 2008, 11:30 pm

> davemplatt@yahoo.com wrote:
>
>>> davempl...@yahoo.com wrote:
>>> > Hi-
>>> > We are replacing our ceramic tile floor and sub floor and have
>>> > discovered that there is some minor wood rot on the tops of some
>>> > of the beams (about 1/2 inch deep).  Is it possible to repair
>>> > this damage and would that pass an inspection in the future?  If
>>> > so, what are the best ways to repair this type of rot?
>>> > Any advice would be greatly appreciated.  Thanks!
>>>
>>> Just sister some new ones in. Do you know what I mean when I say
>>> sister?
>>>
>>> --
>>> "You can lead them to LINUX
>>> but you can't make them THINK"
>>> Running Mandriva release 2008.0 free-i586 using KDE on i586
>>
>> I think that you mean just add another 2x4 on the side of the rooted
>> boards, right? Do we need to treat the rot?
> Is it dry rot or from moisture getting in? It should dry out just
> being exposed. If you're concerned take a chisel and remove it.
>
> Yes that's what I mean when I say sister. You might want to screw the
> 2 X in instead of nailing. Nailing can cause cracks or drywall nails
> to show up on other side.

Won't say that using screws is necessary but you might want to add not to
use drywall screws. Very brittle, thin necks and can snap over time with
natural movement. Can also snap with torque on install.

PexSupply Save 10 468x60
Posted by Joe on May 10, 2008, 4:36 pm
davemplatt@yahoo.com wrote:

> I think that you mean just add another 2x4 on the side of the rooted
> boards, right? Do we need to treat the rot?

bzzt. wrong. I've 'never' seen a 2X4 floor joist.

Posted by Colbyt on May 10, 2008, 6:46 pm


I think that you mean just add another 2x4 on the side of the rooted
boards, right? Do we need to treat the rot?

If you do not understand loads and beams, sister them with the same size as
the existing member.

If the joists are 2x8 use a 2x8. You may waste a little wood but you can't
go wrong doing it this way.



--
Colbyt
Please come visit www.househomerepair.com



Page 2 of 2       << first < 1 2
Similar ThreadsPosted
subfloor for new wood flooring February 22, 2006, 6:58 am
Wood Floor - Subfloor question August 10, 2006, 2:14 pm
question about mold on wood subfloor November 10, 2008, 1:15 am
MDF vs. OSB for Subfloor August 22, 2006, 10:03 pm
Replacing Subfloor September 22, 2005, 5:01 pm
bin sealer on a new subfloor? November 9, 2005, 11:39 pm
How to Construct Subfloor December 4, 2005, 6:47 pm
insulating subfloor December 16, 2005, 5:57 am
Delta subfloor February 11, 2006, 9:47 am
Subfloor Nailing February 23, 2006, 12:52 am

Contact Us | Privacy Policy

XML SitemapXML Sitemap