Home Page link

brick wall support

Home Repair - - If it ain't broken, don't fix it. Otherwise look here. 

Bookmark this page:  YahooMyWeb Yahoo!  Google Google  Windows Live Favorites Windows Live  del.icio.us del.icio.us  digg digg  Add to Netscape Netscape
Subject Author Date
brick wall support Belial Black 07-07-2005
If you were  Registered and logged in, you could reply and use other advanced thread options
Posted by Belial Black on July 7, 2005, 9:45 pm
I've got three brick structures with adjoining walls. At some point in the
last 110 years, an unknown joker decided that he wanted to add a couple of
doorways through the common walls. Rough holes were knocked though the
walls never being properly braced or supported. Amazingly, there aren't yet
any stress cracks or related structural damage but I don't care to press my
luck.
The walls are 12" thick and approx 3' wide. I'm guessing that I need to just
knock a few more bricks out across the top and add some horizontal wood
supports. My question is what type of wood is appropriate here. I'm sure
that the typical HD 2x12 pine plank is totally insufficient for that type
of load. Any thoughts?
-BB
Posted by BobK207 on July 8, 2005, 1:03 am
The walls are 3' wide? Or the opening is 3' wide?
How much brick / structure above the opening?
How much support you need depends on the load above the opening.
cheers
Bob
Posted by Belial Black on July 8, 2005, 8:54 am
BobK207 wrote:
show/hide quoted text
Sorry, the openings are about 3' wide.
show/hide quoted text
This is on the first floor of a two-story wall.
Posted by tbasc on July 8, 2005, 6:39 am
If it were my problem, I'd pay a structural engineer to look at the
holes and surrounding conditions above and below. Interview engineers
until you find one with experience in existing masonry structures. Some
engineers are excellent at new work and not comfortable with old work.
(E.G., 100 year old brick building in an area of questionable soils
with large stepped crack in one outer wall. One engineer recommended
tearing it down while a second recommended monitoring the crack width
for movement. Thirty years later, the building is still standing.)
Posted by Rick on July 8, 2005, 9:40 am
show/hide quoted text
in the
show/hide quoted text
couple of
show/hide quoted text
the
show/hide quoted text
aren't yet
show/hide quoted text
press my
show/hide quoted text
to just
show/hide quoted text
wood
show/hide quoted text
sure
show/hide quoted text
type
show/hide quoted text
Steel might work nicely. As others have pointed out, the tributory
load above each door will determine size and material of the header.
There's an interesting article in the June 2005 Journal of Light
Construction on adding a 12 foot wide exterior door in a brick wall 12
inches thick and 30 feet high...
Similar ThreadsPosted
support underneath old brick load bearing wall September 9, 2009, 2:32 pm
Can a metal stud wall support a 52" flatscreen February 23, 2008, 4:22 pm
wiring up a brick wall June 20, 2005, 11:00 am
1/4" brick over wall in kitchen July 29, 2006, 9:57 pm
Wiring through brick wall October 2, 2009, 4:24 pm
how to remove old roofing tar from brick wall March 30, 2007, 5:18 pm
Window replacement in structural brick wall July 31, 2005, 5:10 pm
Installing a window type A/C unit in a brick wall June 30, 2005, 11:38 pm
Bathroom vent line hole in brick wall? May 29, 2006, 11:18 am
Pull Sagging Trellis to Exterior Brick Wall September 4, 2006, 6:52 pm

Contact Us | Privacy Policy

XML SitemapXML Sitemap