Posted by Pyro70_30 on May 4, 2008, 5:37 pm
My sewer lateral is broken about 8" from my foundation and is about 3"
lower at the septic end. hoe do I fix this?

Posted by Speedy Jim on May 4, 2008, 7:06 pm
Pyro70_30 wrote:
> My sewer lateral is broken about 8" from my foundation and is about 3"
> lower at the septic end. hoe do I fix this?


Obviously, excavate to allow access.

Cast iron?
Vitrified clay?
ABS/PVC?
Orange (ugh) burg?

Trim the broken stub from the house.
For cast iron or clay I would use a
masonry saw blade (gently) or even
a Dremel type tool with cutoff disc.

Make sure the stub remaining is sound and
won't crack further in the future.

If the septic end has really dropped 3"
due to settling, excavate enough distance
so that you can couple in a new section using
45 EL's.

Get a pair of these to match the pipe material:
http://www.fernco.com/coupling.asp

Jim

Posted by Speedy Jim on May 4, 2008, 7:26 pm
Speedy Jim wrote:

> Pyro70_30 wrote:
>
>> My sewer lateral is broken about 8" from my foundation and is about 3"
>> lower at the septic end. hoe do I fix this?
>
>

> If the septic end has really dropped 3"
> due to settling, excavate enough distance
> so that you can couple in a new section using
> 45 EL's.

<edit> Probably can't fit even 45's in;
maybe 22 1'2 EL's or just let the Ferncos
absorb the drop...
Jim

Posted by Big_Jake on May 5, 2008, 12:06 am
> Speedy Jim wrote:
> > Pyro70_30 wrote:
>
> >> My sewer lateral is broken about 8" from my foundation and is about 3"
> >> lower at the septic end. hoe do I fix this?
>
> > If the septic end has really dropped 3"
> > due to settling, excavate enough distance
> > so that you can couple in a new section using
> > 45 EL's.
>
> <edit> Probably can't fit even 45's in;
> maybe 22 1'2 EL's or just let the Ferncos
> absorb the drop...
> Jim

6" clay with a Dremel tool??? You must have lots of patience. I like
a snap cutter (the cast iron kind) even on clay.

JK

Similar ThreadsPosted
Trenchless sewer lateral replacement - Impeded by heavy rains? December 12, 2006, 1:07 pm
HELP!!! Leak in water service lateral! January 29, 2008, 1:38 pm
FOLLOW UP: Leak in water service lateral January 30, 2008, 9:58 pm
PVC Sewer vs DWV September 23, 2006, 1:01 am
ROI for Sewer Connection June 16, 2005, 1:00 am
Fire and Sewer Gas January 23, 2006, 11:11 pm
Sewer Connections July 30, 2006, 8:05 pm
Silly Sewer August 14, 2006, 12:57 am
Sewer gas from toilet August 21, 2006, 12:51 pm
Sewer Remediation October 26, 2006, 9:54 am

Contact Us | Privacy Policy

XML SitemapXML Sitemap