flue pipe size for venting water heater

Home Repair - - If it ain't broken, don't fix it. Otherwise look here. 

Bookmark this page:  YahooMyWeb Yahoo!  Google Google  Windows Live Favorites Windows Live  del.icio.us del.icio.us  digg digg  Add to Netscape Netscape
Subject Author Date
flue pipe size for venting water heater bill allemann 08-27-2007
If you were  Registered and logged in, you could reply and use other advanced thread options
Posted by bill allemann on August 27, 2007, 6:02 pm
On common natural draft NG water heaters, I usually see 4" vent pipe, but I
was looking at specs on a 40gal unit on the Ruun web site, and the chart
shows 3" for residential sizes up to 60 gallons. Somewhere else I was
reading that it is not a good idea to have oversize flue vents on gas
appliances. I can see where oversize vents would also be an energy waster.
Are a lot of people installing vents that are too large?
Anyone know of a good reference for sizing vents.



Posted by Speedy Jim on August 27, 2007, 6:45 pm
bill allemann wrote:
> On common natural draft NG water heaters, I usually see 4" vent pipe, but I
> was looking at specs on a 40gal unit on the Ruun web site, and the chart
> shows 3" for residential sizes up to 60 gallons. Somewhere else I was
> reading that it is not a good idea to have oversize flue vents on gas
> appliances. I can see where oversize vents would also be an energy waster.
> Are a lot of people installing vents that are too large?
> Anyone know of a good reference for sizing vents.
>
>

Often, it comes down to what the local
inspection requirements are. Some cities
won't permit 3" vent.

The draft hood bypasses most of the air
around the heater in standby mode so I
doubt that losses are significantly
different for 3" or 4".

Jim

Posted by Big_Jake on August 27, 2007, 8:55 pm
> bill allemann wrote:
> > On common natural draft NG water heaters, I usually see 4" vent pipe, but I
> > was looking at specs on a 40gal unit on the Ruun web site, and the chart
> > shows 3" for residential sizes up to 60 gallons. Somewhere else I was
> > reading that it is not a good idea to have oversize flue vents on gas
> > appliances. I can see where oversize vents would also be an energy waster.
> > Are a lot of people installing vents that are too large?
> > Anyone know of a good reference for sizing vents.
>
> Often, it comes down to what the local
> inspection requirements are. Some cities
> won't permit 3" vent.
>
> The draft hood bypasses most of the air
> around the heater in standby mode so I
> doubt that losses are significantly
> different for 3" or 4".
>
> Jim

Locally, we can't use a 3" vent if the water heater is the only
appliance on the chimney.

JK


Similar ThreadsPosted
Water heater flue and radon mitigation pipe in close proximity - fire hazard?? April 30, 2007, 3:20 pm
Water Heater Flue Baffle November 13, 2005, 8:53 am
Furnace/water heater Flue liner May 17, 2007, 10:50 am
Water pipe size August 2, 2005, 8:29 pm
What size hot water pipe should I use? April 3, 2008, 7:35 am
Re: Plumbing: What size hot water pipe do I need? April 3, 2008, 9:14 am
Re: Plumbing: What size hot water pipe do I need? April 3, 2008, 9:50 am
Sorry about the double post Re: Hot water pipe size April 3, 2008, 7:39 am
Venting Tankless Hot Water Heater December 9, 2005, 5:34 pm
propane water heater venting January 9, 2006, 8:41 pm

Contact Us | Privacy Policy

XML SitemapXML Sitemap