rebar size for footer?

Home Repair - - If it ain't broken, don't fix it. Otherwise look here. 

Bookmark this page:  YahooMyWeb Yahoo!  Google Google  Windows Live Favorites Windows Live  del.icio.us del.icio.us  digg digg  Add to Netscape Netscape
Subject Author Date
rebar size for footer? mike 06-06-2006
If you were  Registered and logged in, you could reply and use other advanced thread options
Posted by mike on June 6, 2006, 9:07 pm
hey,

got an 8" footer for a 3 wall - 15' Long x 10"Wide x 9' High screened
enclosure with a 3" Elite insulated roof.

do you think #3 rebar (3/8") all around will suffice? we're using fiber
concrete.

some folks are telling me the rebar is overkill. what do you think?

thanks,

mike



Electric Radiant Heat 468x60
Posted by BobK207 on June 7, 2006, 1:56 am

mike wrote:
> hey,
>
> got an 8" footer for a 3 wall - 15' Long x 10"Wide x 9' High screened
> enclosure with a 3" Elite insulated roof.
>
> do you think #3 rebar (3/8") all around will suffice? we're using fiber
> concrete.
>
> some folks are telling me the rebar is overkill. what do you think?
>
> thanks,
>
> mike

How much less rebar could you use?

Seriously, if you want the footer to hold together after the concrete
cracks you'll need at least some rebar.

cheers
Bob


Posted by EXT on June 7, 2006, 8:27 am
Just on general principal I would put at least 2 rows of 1/2" rebar. There
is no such thing as overkill, just better than minimum code.

>
> mike wrote:
>> hey,
>>
>> got an 8" footer for a 3 wall - 15' Long x 10"Wide x 9' High screened
>> enclosure with a 3" Elite insulated roof.
>>
>> do you think #3 rebar (3/8") all around will suffice? we're using fiber
>> concrete.
>>
>> some folks are telling me the rebar is overkill. what do you think?
>>
>> thanks,
>>
>> mike
>
> How much less rebar could you use?
>
> Seriously, if you want the footer to hold together after the concrete
> cracks you'll need at least some rebar.
>
> cheers
> Bob
>



Posted by on June 11, 2006, 4:06 pm

>hey,
>
>got an 8" footer for a 3 wall - 15' Long x 10"Wide x 9' High screened
>enclosure with a 3" Elite insulated roof.
>
>do you think #3 rebar (3/8") all around will suffice? we're using fiber
>concrete.
>
>some folks are telling me the rebar is overkill. what do you think?
>
>thanks,
>
>mike
>
Florida code is two #5s

Similar ThreadsPosted
Perimeter drain on top of footer? January 6, 2007, 1:10 pm
Footer Drain Clogged with Sediment January 7, 2007, 10:17 am
Neoprene Washers: Trade Size vs Actual Size July 5, 2005, 7:28 am
Rebar U October 14, 2007, 8:47 pm
Cutting 1/2" rebar February 7, 2006, 12:57 pm
Removing rebar from the ground? August 31, 2006, 9:35 pm
rebar protrusion problem November 8, 2008, 4:21 pm
Do I need to redo the wire mesh or rebar? July 31, 2005, 8:33 pm
electric rebar cutter benders July 13, 2006, 11:02 am
3' X 5' X 8" thick slab. rebar required? September 2, 2006, 1:59 pm

Contact Us | Privacy Policy

XML SitemapXML Sitemap