Posted by Mook Johnson on August 9, 2006, 8:46 am
In my situation the Nat gas and fies box are far apart. I'm installing the
generator near the nat gas and running wire to the fuese box where the
transfer switch will be.

Its a 15kW unit so large (#2 minimum) wire will be needed to carry the
single phase power to the transfer switch.

I'm having trouble finding this in a bundle. Will I have to run individual
wires in a conduit? The run is ~140 ft.

Where's a good source for electrical wire of this size?




AppliancePartsPros.com, Inc.
Posted by sparty on August 9, 2006, 9:31 am

Mook Johnson wrote:
> In my situation the Nat gas and fies box are far apart. I'm installing the
> generator near the nat gas and running wire to the fuese box where the
> transfer switch will be.
>
> Its a 15kW unit so large (#2 minimum) wire will be needed to carry the
> single phase power to the transfer switch.
>
> I'm having trouble finding this in a bundle. Will I have to run individual
> wires in a conduit? The run is ~140 ft.
>
> Where's a good source for electrical wire of this size?

Well 15K Watts = 62.5 Amps.

You should be able to use 4 guage NM/B Wire IMO. That will have your 2
hots, neutral, and ground wire in it. From my understanding, this wire
can handle 70 AMPS up to about 130 feet for 2% voltage drop or less.
It can handle 60 AMPS up to about 150 feet for 2% voltage drop or less.
That would tell me that it should be able to handle up to 65
AMPS(15.6kW) for 140 feet.

When I ran a subpanel in my garage, I used 4 guage NM/B wire. I could
not find this at your standard Home Depot / Lowes places. However, a
quick look on Yahoo Yellow Pages or in your phone book for electrical
suppliers, you can ask around and find it easy. It did hit my pocket
book good for about $2.20 / foot.


Posted by Eric in North TX on August 9, 2006, 10:58 am

My default response would be running it in conduit, it keeps the
rodents off of it, and the individual wires are usually cheaper than
the bundle, off-setting at least part of the cost of the conduit.


Posted by Pete C. on August 9, 2006, 1:32 pm
Eric in North TX wrote:
>
> My default response would be running it in conduit, it keeps the
> rodents off of it, and the individual wires are usually cheaper than
> the bundle, off-setting at least part of the cost of the conduit.

Depending on how accurate the 140' measurement is, you're also close to
500' for the three conductors (reduced size ground) so you may get a
better price buying a full spool. Still need to buy just 140' or so of
the smaller wire for the ground.

Pete C.

Posted by Edwin Pawlowski on August 10, 2006, 1:19 pm

>
> Where's a good source for electrical wire of this size?

I know this sound radical, but I'd try an electrical supply house.



Similar ThreadsPosted
Running wires from the attic to the basement October 31, 2008, 12:51 pm
Running wires... March 21, 2006, 6:25 pm
running pipes and wires through walls July 5, 2006, 7:53 pm
how to get rid of large paper hornet/wasp nest in attic? November 8, 2007, 11:42 am
Attic vent - Cutting large rectangular hole in stucco October 19, 2005, 9:52 pm
Preheating water by running pipes through attic? August 5, 2008, 6:39 pm
Adding new Circuits to Room Addition... 2 wires or 2 wires + Ground? March 20, 2008, 3:48 pm
Utility Knife February 23, 2006, 1:08 am
Utility bills February 22, 2007, 12:23 pm
Alternative utility providers October 13, 2005, 6:31 am

Contact Us | Privacy Policy

XML SitemapXML Sitemap