Posted by Chuck (in SC) on July 21, 2007, 12:14 am
wrote:
>Chuck (in SC) wrote:
>
>> I know we discuss it here very often.. but now I need a refresher..
>> Working on a well system for a submersible pump. Had a bad gauge on
>> it and was at times not wanting to cut off at high pressure...
>>
>> I replaced the gauge, and cut in / out switch. and pre loaded air
>> charge in bladder tank.. per tank instructions ie: "with no pressure
>> or water in bottom of tank, air pressure in bladder should be 2 lbs
>> less than cut in pressure of switch"
>> The switch is in at 40, cut out at 60..
>>
>> Shouldn't this switch /relay be closed when it's sitting on the
>> shelf.. it being less than 40 psi?
>
>Sounds like it should be. Are you sure that you have the correct
>terminals (there may be both NO and NC terminals).
>The ones that am am familiar with have a cover that you can
>take off and see the contacts.
nope.. single throw..
>>
>> I want to think I've got a bad switch.. it's a Lowes made in china..
>> Won't be going back there (the old home place) till Sunday.. Any ideas
>> are appreciated..
>>
>> Chuck (in SC)
|